72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use

Product Details
Customization: Available
After-sales Service: 1 Year Free Service and Life-Time Service
Warranty: 1 Years or 1500 Running Hours
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100000000 RMB
Plant Area
13380 square meters
  • 72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
  • 72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
  • 72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
  • 72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
  • 72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
  • 72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
Find Similar Products
  • Overview
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
YDNC-58
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
AC Rotating Exciter
Engine Brand
Cummins
Engine Model
4BTA3.9-G2
Engine Power
67kw
Rated Voltage
220/380V
Rated Current
104.4A
Frequency
50/60Hz
Certificate
CE ISO Saso
Transport Package
for Open Type, Packing with Plywood Case; for Sile
Specification
diesel engine
Trademark
YDNPOWER
Origin
Weifang China
HS Code
8502110000
Production Capacity
500 Sets /Month

Product Description

 
58kw 72.5kVA CUMMINS Diesel Electric Generator Set
Genset Model YDNC-58
Rated Power (kW/kVA) 58/72.5
Rated Current (A) 104.4
Dimension (mm) 1850*720*1250
Gross Weight (kg) 830
Diesel engine Brand CUMMINS
Model 4BTA3.9-G2
Configuration Four-stroke,Water-cooling,Direct Injection,4-L type
Rated Power (kW/kVA) 67/84
Rated Speed (rpm) 1500
Cylinder No. 4
Bore*Stroke (mm) 102×120
Displacement(L) 3.9L
Intake Turbocharger
Oil Consumption (g/Kw*h) 216@100% load
Starting method 24V DC
Alternator Brand FARRAND
Model FLD-58
Rated Power (kW/kVA) 58/72.5
Materials 100% pure copper
Efficiency 92.50%
Voltage Regulation <=±1
Voltage Regulation Brushles, Self Excitation
Insulation Class H
Control System Brand SMARTGEN
Model HGM6110
Working Voltage DC8.0V to DC35.0V, continuous
Overall Dimensions (mm) 197*152*47
Panel Cutout (mm) 186*141
Working Condition Temperature: (-25~70)ºC; Humidity: (20~90)%
Weight 0.56kg


 

why choose us

1,We have passed ISO9001 and EU CE certification, and effectively improved the quality of our products

2,You have our promise- 24*7 Lifelong after-sales service

3,10000+cases enable us to have rich experiences in troubleshooting. We can provide reliable and fast technical support for customers.



 

72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use

FAQ

Q1: Are you a trading company or a manufacturer?
Answer: We are a factory

Q2: What is your power range of your diesel generator?
A: We can provide 10KW-1500KW diesel generator and comprehensive power supply solutions for you

Q3: What is the delivery time?
A: 4-6 weeks

Q4: What is your minimum order quantity(MOQ)?
A: 1 set.

Q3: What are your terms of payment?
Answer: 30% by TT in advance and 70% balance before shipment.

Q4: What is your warranty period?
A: Our warranty period is 1 year or 1000 hours, whichever comes first. But according to some special items, we can extend the warranty period.

Q5: Do you provide OEM services?
A: Yes.

Q6: How can I trust you?
A:  If you are not satisfied with the pictures, videos, boarding reports, load tests, customer experience and sales staff's understanding of the generators you are interested in, we invite you to visit our spacious storage yards and stores to witness your generators. Carry out a load test and check our professional operations here.

Q7: What should I do after I receive the generator set?
Answer: Please read the operation manual carefully after obtaining the generator.
The generator is attached with the user manual. With Operation, Installation, Maintenance and Repair Guide.

 
Company Profile
72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use

 

72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use
72.5kVA Cummins Diesel Generator with Silent Canopy for Prime and Emergency Use

 



 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier