• 250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas
  • 250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas
  • 250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas
  • 250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas
  • 250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas
  • 250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas

250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas

Warranty: 1 Years or 1500 Running Hours
Output Type: AC Three Phase
Rated Voltage: 220/380V
Engine Speed: 1500/1800rpm
Frequency: 50/60Hz
Certificate: CE ISO Saso
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Alternator
Ydn/Leroy-Somer/ABB
Starting Method
Electric Start
Transport Package
for Open Type, Packing with Plywood Case; for Sile
Trademark
YDNPOWER
Origin
Weifang China
HS Code
8502110000
Production Capacity
500 Sets /Month

Product Description

 
Model YDNC-250
Rated power (kW/KVA) 250/312.5
Rated current (A) 450
Rated Voltage(V) 230/400
Rated Frequency(Hz) 50
Size (mm) 3800*1600*2200
Weight (kg) 3700
Engine Model K19N
  Type Water-cooled, 4-stroke,6 cylinder in-line
  Rated Power(kW/KVA) 300
  Rated Speed(rpm) 1500
  Cylinder No. 6
  Bore*Stroke(mm) 159×159
  Cooling Method Water-cooled
  Oil Consumption(g/KWH) <1
  Gas Consumption(m3/h) 75
  Starting method 24V DC
Alternator Brand Farrand
  Model FLD-250
  Rated Power(kW/KVA) 250/312.5
  Voltage Regulation <=±1
  Excitation mode Brushless, Self Excitation
  Insulation Class H
Control 
System
Model Smartgen HGM6110N
  Working Voltage DC8.0V to DC35.0V
  Overall Dimensions 197 mm x 152 mm x 47mm
  Panel Cutout 186mm x 141mm
  Working Condition Temperature: (-25~70)ºC; Humidity: (20~90)%
  Weight 0.56kg
Special notes:
The definition of generator power is as follows:
Rated Power (PRP):
1. The running time is unlimited every year.
2. In a 250 hours continuous period, the average load rate should not exceed 80% .
3. Under 100% load, the total running hours should be no more than 500 hours in one year period;

Requirements for natural gas:

  1.  The methane content should not be lower than 95%.
  2.  The gas temperature should be between 0-40 ºC.
  3.  No impurity should be in the gas. Water in the gas should be less than 20g/Nm3.
  4.  Heat value should be at least 8500kcal/m3, if less than this value, the power of the engine will be declined.
  5.  Gas pressure should be 3-100KPa, if the pressure is less than 3KPa, booster fan is necessaryand pressure relief device should be added if the value is higher than 100KPA;  
  6.  The gas should be dehydrated and desulfurized. Make sure that there is no liquid in the gas. H2S<200mg/Nm3
Natural gas generator unit delivery status
 
SN Name Qty Brand Remark
1 Natural gas engine 1 set YDN Displacement 18.9L,1500rpm
2 Alternator 1 set Farrand 50Hz, 230/400V
3 Common Base 1 set YDN POWER Steel 
4 GAS train 1 set YDN POWER GAS pressure regulator,pressure gauge,back-fire arrester,ball valve
5 Battery 1 set Wanli Maintenance free battery
6 Cooling system 1 set Datong Water Cooling
7 Exhaust system 1 set YDN POWER Exhaust and muffler
8 Parts and tools 1 set YDN POWER Spark plug and wrench,air filter
250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas250kw/312.5kVA Ydn Natural Gas Generator Set Petroleum Associated Gas

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100000000 RMB
Plant Area
13380 square meters