400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply

Product Details
Customization: Available
After-sales Service: 1 Year Free Service and Life-Time Service
Warranty: Three Years or 3000 Running Hours
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100000000 RMB
Plant Area
13380 square meters
  • 400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
  • 400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
  • 400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
  • 400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
  • 400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
  • 400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
Find Similar Products
  • Overview
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
YDN-GC-400
Output Type
AC Three Phase
Gas Source
Gas
Certification
CE, ISO
Power
>200kW
Standard
Standard
Rated Power (Kw/kVA)
400/500
Rated Voltage
220/380
Engine Model
Gta38
Rated Current (a)
720
Size (mm)
4550*2010*2510
Weight (Kg)
7500
Cooling Method
Water-Cooling
Gas Consumption(G/Kwh)
≤180@100%Load
Starting Method
24V DC
Speed(Rpm)
1500
Frequency
50Hz
Certificate
CE ISO Saso
ECU Brand
Woodward
Transport Package
Customized
Specification
open type
Trademark
YDNPOWER
Origin
China
HS Code
8502200000
Production Capacity
500 Sets /Month

Product Description

400kW 500kva YDN Silent   electric generator
 
Model YDNC-400L
Rated power (kW/KVA) 400/500
Rated current (A) 720
Size (mm) 4550*2010*2510
Weight (kg) 7500
Engine Model GTA38N
Type Four-stroke, Water-cooling          Direct Injection, V12-type
Rated Power(kW) 450
Rated Speed(rpm) 1500
Cylinder No. 12
Bore*Stroke(mm) 159×159
Cooling Method Water-cooling
Oil Consumption(g/KWH) 1
Gas Consumption(g/kwh) ≤160@100%Load
Starting method 24V DC
Control System Brand FARRAND
Model FLD-400
Rated Power(kW/KVA) 400/500
Efficiency 97.5%
Voltage Regulation <=±1
Excitation mode Brushless, Self Excitation
Insulation Class H
Control System Model Smartgen 9510
Working Voltage DC8.0V - DC35.0V
Overall Dimensions 266 mm x 182 mm x 45 mm
Panel Cutout 214mm x 160mm
Working Condition Temperature:(-25~+70)°C Humidity:(20~93)%
Weight 0.95kg
GENERATOR SET REQUIMENTS FOR LPG:
(1) Propane butane mixed gas
(2) The natural gas temperature should be between 0-60 ºC.
(3) No impurity should be in the gas. Water in the gas should be less than 20g/Nm3.
(4) Gas pressure should be 3-100KPa, if the pressure is less than 3KPa, booster required
(5) The gas should be dehydrated and desulfurated. Make sure that there is no liquid in the
   gas. H2S<200mg/Nm3.
 
 

Why Choose us

1,We have passed ISO9001 and EU CE certification, and effectively improved the quality of our products

2,You have our promise- 24*7 Lifelong after-sales service

3,10000+cases enable us to have rich experiences in troubleshooting. We can provide reliable and fast technical support for customers.



 

400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply

FAQ

Q1: Are you a trading company or a manufacturer?
Answer: We are a factory

Q2: What is your power range of your diesel generator?
A: We can provide 10KW-1500KW diesel generator and comprehensive power supply solutions for you

Q3: What is the delivery time?
A: 4-6 weeks

Q4: What is your minimum order quantity(MOQ)?
A: 1 set.

Q3: What are your terms of payment?
Answer: 30% by TT in advance and 70% balance before shipment.

Q4: What is your warranty period?
A: Our warranty period is 1 year or 1000 hours, whichever comes first. But according to some special items, we can extend the warranty period.

Q5: Do you provide OEM services?
A: Yes.

Q6: How can I trust you?
A:  If you are not satisfied with the pictures, videos, boarding reports, load tests, customer experience and sales staff's understanding of the generators you are interested in, we invite you to visit our spacious storage yards and stores to witness your generators. Carry out a load test and check our professional operations here.

Q7: What should I do after I receive the generator set?
Answer: Please read the operation manual carefully after obtaining the generator.
The generator is attached with the user manual. With Operation, Installation, Maintenance and Repair Guide.

 
Company Profile
400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply

 

400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply
400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply

400kw Natural Gas Generator Unit Power Station Plant Generator Standby Power Supply


 

Requirments for natural gas

1.Methane should be at least 85%
2.The natural gas temperature should be between 0-60 ºC
3. No inpurity should be in the gas. Water in the gas should be less than 20g/Nm3.
4. Heat value should be at least 8500kcal/m3, if less than this value, the power of the engine will be declined.
5. Gas pressure should be 8-14KPa, if the pressure is less than 3KPa, booster fan is necessary.
6.The gas should be dehydrated and desulfurated. Make sure that there is no liquid in the gas. H2S<200mg/Nm3


 